Zn85
Zn85

Zn85

ZN85-40.5/2000-31.5 indoor high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is suitable
Basic Info.
Model NO. ZN85
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB
Certification ISO9001-2000, CE, CCC
Closing Time 50-100ms
Average Opening Speed 1.6-2.0m/S
Opening Time 30-60ms
Rated Peak Withstand Current 63-80ka
Rated Short Circuit Duration 4s
DC Component 40%
Average Closing Speed 0.4-0.8m/S
Power Frequency Withstand Voltage 95kv
Rated Short Circuit Breaking Current 20-31.5ka
Rated Operation Sequence O-0.3s-Co-180s-Co
Lightning Impulse Voltage 185kv
Rated Frequency 50/60Hz
Transport Package Wooden Box Shipping
Specification 1194*873*1695mm
Trademark CNKC
Origin China
Production Capacity 2000PCS/Monthly
Product Description


ZN85-40.5/2000-31.5 indoor high voltage vacuum circuit breaker (hereinafter referred to as circuit breaker) is suitable for three-phase AC 50Hz, rated voltage 40.5KV power system, and can be used in industrial and mining enterprises, power plants and substations as load current, overload current and fault current.The circuit breaker and operating mechanism are arranged up and down to reduce the depth of the circuit breaker effectively.The three-phase arc extinguishing chamber and the connected charged body are separated by three independent epoxy resin insulated tubes, which constitute a composite insulation structure. The circuit breaker can meet the requirements of air distance and climbing distance under normal operation conditions, and effectively reduce the volume of the circuit breaker. The vacuum arc extinguishing chamber of the main electric circuit and the static-electric connection are installed in the insulated cylinder, so that the phase spacing is only 300mm. The electrical connection of the main circuit adopts fixed connection, which has high reliability. The insulation barrel is mounted above the breaker frame.The spring operating mechanism specially designed for this new type of circuit breaker is installed in the framework of the circuit breaker. Its structural characteristics are more suitable for the layout of the circuit breaker up and down, and become an integral part of the overall structure of the circuit breaker. The mechanism design is simple, and the output curve and its performance are more suitable for the characteristics and requirements of 40.5kV vacuum circuit breaker.The overall layout is reasonable, beautiful and simple. Compact size, flexible operation, reliable electrical performance, long service life, easy maintenance, maintenance free mechanism characteristics.The circuit breaker is suitable for frequent operation and many occasions and places with harsh operating conditions.


1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.4. Installation gradient not exceed 5.5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.6. Any specific requirement, consult with manufactory.


Zn85-40.5kv 1250-2000A Three-Phase AC Indoor High Voltage Vacuum Circuit Breaker Auto Reclose


A corner of the production workshop

Zn85-40.5kv 1250-2000A Three-Phase AC Indoor High Voltage Vacuum Circuit Breaker Auto Reclose

Zn85-40.5kv 1250-2000A Three-Phase AC Indoor High Voltage Vacuum Circuit Breaker Auto Reclose

Zn85-40.5kv 1250-2000A Three-Phase AC Indoor High Voltage Vacuum Circuit Breaker Auto Reclose


Product packaging

Zn85-40.5kv 1250-2000A Three-Phase AC Indoor High Voltage Vacuum Circuit Breaker Auto Reclose


Product application case