Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
HomeHome > Products > High Voltage Outdoor Vacuum Circuit Breaker > Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB
Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB

ZW7-40.5 Outdoor Voltage Vacuum Circuit Breaker With Central Operating Mechanism General DescriptionZW7-40.5 series of o
Basic Info.
Model NO. ZW7-40.5
Poles Number 3
Type Circuit Breaker
Function Conventional Circuit Breaker, Overcurrent Protection, OVP(Overvoltage Protection)
Certification VDE, ISO9001-2000, CE, CB, CCC
Rated Frequency 50/60Hz
Mechanism Central Operating Mechansim
Model Number 3 Poles
Rated Current 1250/1600/2000A
Rated Voltage 40.5kv
Transport Package Non-Solid Wooden Case for Export Shipment
Specification IEC: M2-E2-C2
Trademark Longxiang Electric
Origin Baoji, Shaanxi China
HS Code 85389000
Production Capacity 16000sets/Year
Product Description
ZW7-40.5 Outdoor Voltage Vacuum Circuit Breaker With Central Operating Mechanism
General DescriptionZW7-40.5 series of outdoor High Voltage Vacuum Circuit Breaker With Central Operating Mechanism are three phase,A.C 50(60) Hz outdoor high voltage distribution equipment with 40.5kV rated voltage ,which can be used to open or close loading current,over-loading current and short-circuit current, it is widely used in rural electrical network and comply with GB1984-2003 standard.The overall structure of this product adopt porcelain insulator support type,the vacuum interrupter is installed inside the upper insulator,the lower insulator is used for support bottle,three phases are amounted on the same mechanism box,the moving end of vacuum interrupteris connected with operating mechanism through shaft and insulation lever.The operation is easy and convenient.
Applying ambient conditions
1.Ambient temperature:-30ºC~+40ºC2.Ambient humidity:the average humidity of a day should be no more than 95%:the average humidity of a month should be no more than 90%.3.Earthquake intensity:not exceed 8degrees.4.Saturated vapour pressure:the average pressure of a day should be no more than 2.2kPa:the average pressure of a month should be no more than 1.8kPa.5.The height above sea level:≤1000m.6.Air filthy degree: III degrees.7.It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.
Our Factory

Packaging & Delivery.
Packaging DetailsNon-solid wooden case(Stand export package).
Delivery DetailWithin 10~15days from the date of receiving signed sales confirmation by both parties.

Outdoor High Voltage Vacuum Circuit Breaker with Xihari Type Test Report/33 KV VCB